NAV _____IR 3 FAULT
Air Data Inertial Reference Unit (ADIRU)
— RESET PROCEDURE—
- Reset breakers FWC 1 and FWC 2 on the LH and RH reset panels.
- Cycle breaker ADIRU3 115VAC on panel 721VU pos G05.
- Cycle breaker ADIRU3 28VDC on panel 742VU pos F68.
- Cycle breaker ADIRU3 BAT on panel 742VU pos G74.
MEL STATUS: MEL 34-10-01-A