F/CTRL _____FLAP SYS 1/2 FAULT
Slat/Flap Control Computer 1/2 (SFCC)
— RESET PROCEDURE—
Pull & reset
- SFCC 1: Pull Slats B06 Flaps B07
- SFCC 2: Pull Slats R21 Flaps Q21
Pull CBs for: 1 sec
POST: 65 sec
MEL STATUS: 27-51-01


F/CTRL _____FLAP SYS 1/2 FAULT
Slat/Flap Control Computer 1/2 (SFCC)
— RESET PROCEDURE—
Pull & reset
Pull CBs for: 1 sec
POST: 65 sec
MEL STATUS: 27-51-01

All instructions and limitations given in those documents that relate to the resetting of systems both on the ground and in the air must be respected. No reset should be attempted without a thorough appreciation of the technical ramifications. No more than one computer should be reset at any one time. No reset should be attempted in flight unless specifically permitted by the QRH. Maintenance messages remaining after a reset require engineering investigation.