F/CTRL _____FLAP SYS 1/2 FAULT

Slat/Flap Control Computer 1/2 (SFCC)

— RESET PROCEDURE—

Pull & reset

  • SFCC 1: Pull Slats B06 Flaps B07
  • SFCC 2: Pull Slats R21 Flaps Q21

Pull CBs for: 1 sec

POST: 65 sec

MEL STATUS: 27-51-01



Добавить комментарий

Read me first

All instructions and limitations given in those documents that relate to the resetting of systems both on the ground and in the air must be respected. No reset should be attempted without a thorough appreciation of the technical ramifications. No more than one computer should be reset at any one time. No reset should be attempted in flight unless specifically permitted by the QRH. Maintenance messages remaining after a reset require engineering investigation.

If you encounter an ECAM warning or caution that is not available on our website, please take a photo and send it to our Telegram.

Likewise, if you detect any discrepancies on the site, you can report them directly in our Telegram.