AFT Cargo-Compartment Fan Fault A320
1. Possible Causes:
-CONT-AIR COND SYSTEM 1 (47HH)
-wiring
2. Job Set-up Information
A. Referenced Information
Ref. AMM 21-61-00-710-001 Operational Test of the Pack Temperature-Control System
Ref. AMM 21-61-34-000-002 Removal of the Air-Conditioning System Controller
Ref. AMM 21-61-34-400-002 Installation of the Air-Conditioning System Controller
Ref. ASM 21-63-03
3.Fault Confirmation
SUBTASK 21-28-00-710-053-A
A. Test
NOTE: This fault isolation procedure is applicable although the AFT cargo-compartment ventilation system is not installed.
(1) Do the operational test of the pack temperature-control system Ref. AMM 21-61-00-710-001.
4. Fault Isolation
SUBTASK 21-28-00-810-067-C
A. If the test gives the maintenance message FWD CARGO FAN OR SPLY:
-replace the CONT-AIR COND SYSTEM 1 (47HH) Ref. AMM 21-61-34-000-002 and Ref. AMM 21-61-34-400-002.
(1)If the fault continues:
(a)Remove the CONT-AIR COND SYSTEM 1 (47HH) Ref. AMM 21-61-34-000-002.
(b)Do a check and repair the wiring between:
-connector (47HH/AB) pin 4K and GND Ref. ASM 21-63-03.
(c) Install the CONT-AIR COND SYSTEM 1 (47HH) Ref. AMM 21-61-34-400-002.
SUBTASK 21-28-00-710-062-A
B. Do the test given in Para. 3.