Operational Check of Lavatory Smoke Detection by CFDS A320
1. Reason for the Job
Refer to the MPD TASK: 261700-03
OPERATIONAL CHECK OF LAVATORY SMOKE DETECTION BY CFDS TO CONFIRM WARNINGS CAN BE DISPLAYED
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
B. Referenced Information
| REFERENCE | DESIGNATION |
| Ref. 23-73-00-861-001-A | Energize the Cabin Intercommunication Data System (CIDS) |
| Ref. 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| Ref. 24-41-00-861-002-A01 | Energize the Aircraft Electrical Circuits from the APU |
| Ref. 24-41-00-861-002-A02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| Ref. 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| Ref. 24-41-00-862-002-A01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| Ref. 24-41-00-862-002-A02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| Ref. 31-32-00-860-005-A | Procedure to Get Access to the SYSTEM REPORT/TEST FIRE PROT Page |
| Ref. 31-60-00-860-001-A | EIS Start Procedure |
| Ref. 31-60-00-860-002-A | EIS Stop Procedure |
3. Job Set-up
SUBTASK 26-17-00-860-050-A
A. Aircraft Maintenance Configuration
- (1) Energize the aircraft electrical circuits Ref. AMM TASK 24-41-00-861-002.
- (2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only) Ref. AMM TASK 31-60-00-860-001.
- (3) Energize the Cabin Intercommunication Data System (CIDS) Ref. AMM TASK 23-73-00-861-001.
- (4) On one Multipurpose Control and Display Unit (MCDU) get the SYSTEM REPORT/TEST FIRE PROT menu Ref. AMM TASK 31-32-00-860-005.
SUBTASK 26-17-00-865-054-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
| PANEL | DESIGNATION | FIN | LOCATION |
| 49VU | AIR COND/CIDS/SDF/DIR2 ESS | 18WH | C06 |
| 49VU | AIR COND/CIDS/SDF/DIR1 ESS | 15WH | C05 |
| 49VU | COM/CIDS/DIR ESS/2 | 157RH | G02 |
| 49VU | COM/CIDS/DIR ESS/1 | 150RH | G01 |
| 121VU | COM NAV/CIDS/DIR NORM/2 | 156RH | M06 |
| 121VU | COM NAV/CIDS/DIR NORM/1 | 151RH | M05 |
| 122VU | AIR COND/CIDS/SDF/DIR NORM/2 | 14WH | T18 |
| 122VU | AIR COND/CIDS/SDF/DIR NORM/1 | 17WH | T17 |
4. Procedure
SUBTASK 26-17-00-710-050-H
A. Test of the Lavatory Smoke-Detection System
- (1) Do this test procedure:
| ACTION | RESULT |
| 1.On the MCDU:-Push the line key adjacent to the SDCU indication. | On the MCDU:-The CIDS-SDF page comes into view and shows:SDCU FUNCTIONIS INTEGRATED INCIDS DIRECTORS101RH & 102RHCALLED CIDS-SDFx |
| On the MCDU:-Push the NEXT PAGE button. | On the MCDU:-The CIDS-SDF main menu comes into view. |
| 2.On the MCDU:-Push the line key adjacent to the SMOKE WARN TESTS indication. | On the MCDU:-The SMOKE WARNING TESTS page comes into view. |
| 3.On the MCDU:-Push the line key adjacent to the SMK DET LAVATORY TESTS or LAVATORY TESTS indication. | On the MCDU:-The SMOKE DET LAVATORY TESTS menu comes into view. |
| 4.On the MCDU:-Push the line key adjacent to the first SMK DET LAV LOC X TEST indication.NOTE:X is the related lavatory location. | On the MCDU:-The message TEST IN PROGRESS (xS) shows. |
| In the cockpit:On the panels 130VU and 131VU:-The MASTER WARN lights flash.-You hear the Continuous Repetitive Chime (CRC).NOTE:You can cancel the cockpit CRC by pressing the Master Warning P/B switch. | |
| On the MCDU:-The messageON ECAM WARNING DISPLAY MAKE SURE THAT (SMOKE LAVATORY) IS INDICATEDshows. | |
| On the Engine/Warning Display (EWD):-SMOKE LAVATORY SMOKE(red) shows. | |
| 5.On the MCDU:-Push the line key adjacent to the YES indication. | On the MCDU:-The messageIN THE CABIN MAKE SURE THAT (SMOKE LAV X) IS INDICATED ON THE FAP/AIPshows.NOTE:X is the related lavatory location. |
| On the Flight Attendant Panel (FAP):-The SMOKE DETECTION page with the SMOKE RESET touch button comes into view.-The location of the related lavatory shows. | |
| On all Attendant Indication Panels (AIPs):-SMOKE LAV Xshows.NOTE:X is the related lavatory location. | |
| In the cabin:You see and hear the visual and aural indications specified in the Cabin Assignment Module (CAM).NOTE:For a reset of these indications, it is necessary to push the smoke indicator on the related panel. You can also do a reset on a smoke page in view on the Flight Attendant Panel (FAP). | |
| 6.On the FAP or the related AAP (if installed):-Push the SMOKE RESET key. | On the AIPs:-The message SMOKE LAV X goes out of view.NOTE:X is the related lavatory location. |
| On the FAP:-The LAV SMOKE light (red) stays on.-The SMOKE DETECTION page and location of the related lavatory stay into view. | |
| In the cabin:The aural and visual indications as specified in the CAM stop/go out of view. | |
| 7.On the MCDU:-Push the line key adjacent to the YES indication. | On the MCDU:-The TEST OK message shows. |
| In the cockpit: | |
| On the panels 130VU and 131VU:-The MASTER WARN lights go off.-The CRC stops. | |
| On the EWD:-The message SMOKE LAVATORY SMOKEgoes out of view. | |
| On the FAP:-The LAV SMOKE light (red) goes off.-The SMOKE DETECTION page and location of the related lavatory stay into view. | |
| 8.On the MCDU:-Push the line key adjacent to the RETURN indication. | On the MCDU:-The SMK DET LAVATORY TESTS menu comes into view. |
| In the cabin:-Make sure that all visual and aural indications are off. | |
| 9.Do this test again for the smoke detectors of all the other lavatories. |
5. Close-up
SUBTASK 26-17-00-860-051-A
A. Put the aircraft back to its initial configuration.
- (1) On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.
- (2) Do the EIS stop procedure Ref. AMM TASK 31-60-00-860-002.
- (3) De-energize the aircraft electrical circuits Ref. AMM TASK 24-41-00-862-002.