Operational Check of the Cargo-Compartment Smoke Detection by CFDS A320

1.Reason for the Job

Self explanatory

2. Job Set-up Information

A. Work Zones and Access Panels

ZONE/ACCESSZONE DESCRIPTION
210CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD

B. Referenced Information

REFERENCEDESIGNATION
Ref. 24-41-00-861-002-AEnergize the Aircraft Electrical Circuits from the External Power
Ref. 24-41-00-861-002-A01Energize the Aircraft Electrical Circuits from the APU
Ref. 24-41-00-861-002-A02Energize the Aircraft Electrical Circuits from Engine 1(2)
Ref. 24-41-00-862-002-ADe-energize the Aircraft Electrical Circuits Supplied from the External Power
Ref. 24-41-00-862-002-A01De-energize the Aircraft Electrical Circuits Supplied from the APU
Ref. 24-41-00-862-002-A02De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
Ref. 31-32-00-860-005-AProcedure to Get Access to the SYSTEM REPORT/TEST FIRE PROT Page
Ref. 31-60-00-860-001-AEIS Start Procedure
Ref. 31-60-00-860-002-AEIS Stop Procedure

3. Job Set-up

SUBTASK 26-16-00-860-055-A

A. Aircraft Maintenance Configuration

(1) Energize the aircraft electrical circuits Ref. AMM TASK 24-41-00-861-002.

(2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only) Ref. AMM TASK 31-60-00-860-001.

(3) Make sure that the ENGINE/WARNING page shows on the ECAM upper display unit.

(4) On one MCDU get the SYSTEM REPORT/TEST FIRE PROT menu Ref. AMM TASK 31-32-00-860-005.

SUBTASK 26-16-00-865-068-A

B. Make sure that this(these) circuit breaker(s) is(are) closed:

PANELDESIGNATIONFINLOCATION
49VUAIR COND/CIDS/SDF/DIR2 ESS18WHC06
49VUAIR COND/CIDS/SDF/DIR1 ESS15WHC05
49VUCOM/CIDS/DIR ESS/2157RHG02
49VUCOM/CIDS/DIR ESS/1150RHG01
121VUCOM NAV/CIDS/DIR NORM/2156RHM06
121VUCOM NAV/CIDS/DIR NORM/1151RHM05
122VUAIR COND/CARGO/FIRE/EXTIG1WXT19
122VUAIR COND/CIDS/SDF/DIR NORM/214WHT18
122VUAIR COND/CIDS/SDF/DIR NORM/117WHT17

4. Procedure

SUBTASK 26-16-00-710-071-C

A. Test of the Cargo-Compartment Smoke-Detection System

(1) Both CIDS-SDF channels and all cargo-compartment smoke-detectors must be supplied with power for a minimum of 30 seconds before you start the test.

(2) Do this test procedure:

NOTE: Automatic procedures related to the red message will be shown during the test on the ECAM upper display unit. All these procedures, except agent discharge information, can be ignored.

ACTIONRESULT
1.On the MCDU:-Push the line key adjacent to the SDCU or SMOKE indication.On the MCDU:If SDCU indication is displayed:-The CIDS-SDF page comes into view and shows:SDCU FUNCTIONIS INTEGRATED INCIDS DIRECTORS101RH & 102RHCALLED CIDS-SDFxIf SMOKE indication is displayed on the MCDU:-The CIDS-SDF main menu comes into view.
If SDCU indication is displayed on the MCDU:-Push the NEXT PAGE button.On the MCDU:-The CIDS-SDF main menu comes into view.
2.On the MCDU:-Push the line key adjacent to the SMOKE WARN TESTS indication.On the MCDU:-The SMOKE WARNING TESTS menu comes into view.
-Push the line key adjacent to the FWD LDCC TEST indication.-The message IN PROGRESS 10 SEC shows.
-The SMK DET FWD LDCC TEST page comes into view and the message:ON OVHD PANEL AND ECAMWARNING DISPLAYMAKE SURE THAT»SMOKE FWD CARGO SMOKE»IS INDICATEDshows.
On the glareshield panels 130VU and 131VU:-The MASTER WARN lights flash.-You hear the Continuous Repetitive Chime (CRC).
On the ECAM upper display unit:-SMOKE FWD CARGO SMOKE-…AGENT………..DISCHcome into view.
On the CARGO SMOKE panel 22VU:-The SMOKE FWD CARGO warning light comes on.
-Push the line key adjacent to the YES indication.On the MCDU:The SMK DET FWD LDCC TEST page comes into view and the message:TEST OKshows.
In the cockpit:-All smoke warnings and indications are cancelled.
3.On the MCDU:-Push the line key adjacent to the RETURN indication.On the MCDU:-The SMOKE WARNING TESTS menu comes into view.
4.Push the line key adjacent to the AFT LDCC TEST indication.On the MCDU:-The message IN PROGRESS 10 SEC shows.
-The SMK DET AFT LDCC TEST page comes into view and the message:ON OVHD PANEL AND ECAMWARNING DISPLAYMAKE SURE THAT»SMOKE AFT CARGO SMOKE»IS INDICATEDshows.
On the glareshield panels 130VU and 131VU:-The MASTER WARN lights flash.-You hear the CRC.
On the ECAM upper display unit:-SMOKE AFT CARGO SMOKE-…AGENT………..DISCHcome into view.
On the CARGO SMOKE panel 22VU:-The SMOKE AFT CARGO warning light comes on.
-Push the line key adjacent to the YES indication.On the MCDU:-The SMK DET AFT LDCC TEST page comes into view and the message:TEST OKshows.
In the cockpit:-All smoke warnings and indications are cancelled.
5.On the MCDU:-Push the line key adjacent to the RETURN indication.On the MCDU:-The SMOKE WARNING TESTS menu comes into view.

5. Close-up

SUBTASK 26-16-00-860-056-A

A. Put the aircraft back to its initial configuration.

(1) On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.

(2) Do the EIS stop procedure Ref. AMM TASK 31-60-00-860-002.

(3) De-energize the aircraft electrical circuits Ref. AMM TASK 24-41-00-862-002.

Read me first

All instructions and limitations given in those documents that relate to the resetting of systems both on the ground and in the air must be respected. No reset should be attempted without a thorough appreciation of the technical ramifications. No more than one computer should be reset at any one time. No reset should be attempted in flight unless specifically permitted by the QRH. Maintenance messages remaining after a reset require engineering investigation.