Failure of the GPWC A320

1.Possible Causes:

-GPWC (1WZ)

-C/B-EIS/GPWS/115VAC (3WZ)

-short to ground at the wiring between the circuit breaker (3WZ) and the GPWC (1WZ)

2. Job Set-up Information

A. Referenced Information

REFERENCEDESIGNATION
Ref. AMM 34-48-00-740-002BITE Test of the Enhanced EGPWS
Ref. ASM 34-48-01
Ref. AMM 34-48-34-000-001Removal of the GPWC
Ref. AMM 34-48-34-400-001Installation of the GPWC

3. Fault Confirmation

SUBTASK 34-48-00-865-050-A

A. Make sure that this(these) circuit breaker(s) is(are) closed:

PANELDESIGNATIONFINLOCATION
121VUEIS/GPWS/115VAC3WZP07

SUBTASK 34-48-00-740-050-C

B. Test

(1) If the circuit breaker (3WZ) trips, refer to Para. 4. C. of this trouble shooting procedure.

(2) Do the BITE test of the Enhanced GPWS Ref. AMM 34-48-00-740-002.

— If the BITE test is not possible, refer to Para. 4. B. of this trouble shooting procedure.

4. Fault Isolation

SUBTASK 34-48-00-810-050-A

A. If the circuit breaker (3WZ) is closed, and if the BITE test gives the maintenance message GPWC (1WZ):

— replace the GPWC (1WZ) Ref. AMM 34-48-34-000-001 and Ref. AMM 34-48-34-400-001.

SUBTASK 34-48-00-810-051-A

B. If the circuit breaker (3WZ) is closed and if the BITE test is not possible

— do a check for 115VAC at pin AC/2 of the GPWC.

(1) If there is no 115VAC:

— do a check of the wiring of the 115VAC signal from circuit breaker (3WZ) to GPWC (1WZ) Ref. ASM 34-48-01.

(a) If there is no continuity:

— repair the above wiring.

(b) If there is continuity:

— replace the C/B-EIS/GPWS/115VAC (3WZ).

(2) If there is 115VAC:

— do a check of the wiring of the ground signal at GPWC pin AC/3.

(a) If there is no continuity:

— repair the above wiring.

SUBTASK 34-48-00-810-093-A

C. If the circuit breaker (3WZ) is open:

— close this circuit breaker.

(1) If the circuit breaker (3WZ) trips:

— remove the GPWC (1WZ) Ref. AMM 34-48-34-000-001.

— close the circuit breaker (3WZ).

(a) If this circuit breaker stays closed:

— install the GPWC Ref. AMM 34-48-34-400-001

1 If the circuit breaker trips again:

— replace the GPWC Ref. AMM 34-48-34-000-001 and Ref. AMM 34-48-34-400-001.

(b) If this circuit breaker trips again:

— do a check for a short to ground at the wiring between the circuit breaker (3WZ) and the GPWC (1WZ) Ref. ASM 34-48-01.

1 If there is a short to ground:

— repair the above wiring.

2 If there is no short to ground:

— replace the C/B-EIS/GPWS/115VAC (3WZ).

3 Install the GPWC Ref. AMM 34-48-34-400-001.

SUBTASK 34-48-00-740-051-A

D. Do the test given in Para. 3.B.

Read me first

All instructions and limitations given in those documents that relate to the resetting of systems both on the ground and in the air must be respected. No reset should be attempted without a thorough appreciation of the technical ramifications. No more than one computer should be reset at any one time. No reset should be attempted in flight unless specifically permitted by the QRH. Maintenance messages remaining after a reset require engineering investigation.