Loss of the Channel A of the FADEC on Engine 2 A320

1. Possible Causes:

-ECU (4000KS)

-C/B-ENGINE/2/FADEC A/AND EIU 2 (2KS2)

-EIU-2 (1KS2)

-harness J1

-aircraft wiring

2. Job Set-up Information

A. Referenced Information

REFERENCEDESIGNATION
Ref. AMM 71-00-00-710-006Minimum Idle Check
Ref. AMM 73-21-60-000-001Removal of the Electronic Control Unit (ECU)
Ref. AMM 73-21-60-400-001Installation of the Electronic Control Unit (ECU)
Ref. ASM 73-25-05
Ref. ASM 73-25-08
Ref. AMM 73-25-34-000-040Removal of the Engine Interface Unit (EIU)
Ref. AMM 73-25-34-400-040Installation of the Engine Interface Unit (EIU)
Ref. AMM 73-29-00-710-040Operational Test of the FADEC on the ground (with Engine Motoring)

3. Fault Confirmation

SUBTASK 77-00-00-710-193-B

A.           Test

(1)          Do the operational test of the FADEC 2A on the ground (with engine motoring) Ref. AMM 73-29-00-710-040.

4.Fault Isolation

SUBTASK 77-00-00-865-059-A

A.           Table of the circuit breakers used in this procedure:

PANELDESIGNATIONFINLOCATION
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
121VUENGINE/ENG2/FADEC B4KS2Q40

SUBTASK 77-00-00-810-150-A

B.            If the fault symptom is identified by the upper ECAM warning ENG2 FADEC A FAULT and the test of the FADEC 2A gives no maintenace message:

-disconnect the connector J1 from the ECU (4000KS) and do a check for 28VDC at pin J1/13 with the FADEC GND PWR pushbutton switch released (the ON legend is on).

(1) If there is 28VDC:

-replace the ECU (4000KS) Ref. AMM 73-21-60-000-001 and Ref. AMM 73-21-60-400-001.

(a)If the fault continues:

-do a check for circuit breakers (2KS2) close and (4KS2) open.

(b)If the fault continues:

-replace the C/B-ENGINE/2/FADEC A/AND EIU 2 (2KS2).

(2) If there is no 28VDC:

-do a check for 28VDC at EIU 2 (1KS2) pin AC/11 Ref. ASM 73-25-05.

(a)          If there is 28VDC:

-do a check for open or short to ground at the harness J1 between the EIU 2 (1KS2) and the ECU (4000KS), pin AC/7 to pin J1/13. Replace the harness J1 if necessary.

1             If the fault continues:

-make sure that there is no ground signal at EIU 2 (1KS2) pin AA/5B Ref. ASM 73-25-08.

2             If the fault continues:

-replace the EIU-2 (1KS2) Ref. AMM 73-25-34-000-040 and Ref. AMM 73-25-34-400-040.

(b)          If there is no 28VDC:

-do a check for open or short to ground at the aircraft wiring between the circuit breaker (2KS2) and EIU 2 (1KS2) pin AC/11.

1             If there is a short to ground:

-repair the above wiring.

2             If there is no short to ground:

-replace the C/B-ENGINE/2/FADEC A/AND EIU 2 (2KS2).

(c)          Make sure that 28VDC supplies the ESS bus Ref. ASM 73-25-05.

SUBTASK 77-00-00-710-194-A

C. Do a minimum idle check Ref. AMM 71-00-00-710-006.

Read me first

All instructions and limitations given in those documents that relate to the resetting of systems both on the ground and in the air must be respected. No reset should be attempted without a thorough appreciation of the technical ramifications. No more than one computer should be reset at any one time. No reset should be attempted in flight unless specifically permitted by the QRH. Maintenance messages remaining after a reset require engineering investigation.