Operational Test of the FADEC on the Ground (with Engine Motoring) A320

1. Reason for the Job

Self explanatory

2. Job Set-up Information

A. Fixtures, Tools, Test and Support Equipment

REFERENCEQTYDESIGNATION
No specificARGROUND AIR-SUPPLY UNIT(HIGH PRESSURE)

B. Work Zones and Access Panels

ZONE/ACCESSZONE DESCRIPTION
210CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
400POWER PLANT, NACELLES AND PYLONS

C. Referenced Information

REFERENCEDESIGNATION
Ref. 10-11-00-555-013-AInstallation of the Aircraft Protection Equipment
Ref. 10-11-00-555-014-ARemoval of the Aircraft Protection Equipment
Ref. 12-12-29-611-001-AFill the Hydraulic Fluid Reservoir with a Hand Pump
Ref. 12-12-29-611-002-AFill the Hydraulic Fluid Reservoir with a Hydraulic Service Cart
Ref. 12-13-79-610-002-ACheck oil level and replenish Check Pop Out Indicator of EMCD (Electrical Master Chip Detector)
Ref. 12-13-79-610-002-A01Check oil level and replenish (Pressure Filling)
Ref. 24-41-00-861-002-AEnergize the Aircraft Electrical Circuits from the External Power
Ref. 24-41-00-861-002-A01Energize the Aircraft Electrical Circuits from the APU
Ref. 24-41-00-861-002-A02Energize the Aircraft Electrical Circuits from Engine 1(2)
Ref. 24-41-00-862-002-ADe-energize the Aircraft Electrical Circuits Supplied from the External Power
Ref. 24-41-00-862-002-A01De-energize the Aircraft Electrical Circuits Supplied from the APU
Ref. 24-41-00-862-002-A02De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
Ref. 29-14-00-614-002-APressurization of the Hydraulic Reservoirs through the Ground Connector
Ref. 29-14-00-614-002-A01Pressurization of the Hydraulic Reservoirs with the Auxiliary Power Unit (APU)
Ref. 31-32-00-860-012-AProcedure to Get Access to the SYSTEM REPORT/TEST/ENG Page
Ref. 36-12-00-860-001-APressurization of the Bleed System with the APU
Ref. 36-12-00-860-002-APressurization of the Bleed System through the HP Ground Connector
Ref. 78-36-00-010-040-BOpening of the Thrust Reverser Doors
Ref. Fig. FADEC Test Engine Motoring

3. Job Set-up

SUBTASK 73-29-00-869-050-A

A. Safety Precautions

(1)          Remove the protective covers from the probes and sensors before you do this procedure Ref. AMM TASK 10-11-00-555-014.

(2)          Make sure that:

—              the engine,

—              the air intake,

—              the exhaust areas, are clear of equipment, persons, tools, blockages, all unwanted objects and ice.

(3)          Make sure that the fan parts and the engine inlet area are in the correct condition. Make a full inspection of the fan blades.

(4)          Examine the external surfaces of the cowl. Make sure that there are no leaks of fuel and oil at the drain ports.

SUBTASK 73-29-00-861-050-A

B.            Energize the aircraft electrical circuits Ref. AMM TASK 24-41-00-861-002.

SUBTASK 73-29-00-860-050-A

C.            Do a check of the Aircraft Condition:

(1)          On the lower display unit of the ECAM system on the ENG page:

(a)          make sure that the oil level is correct.

1             If it is necessary, do the servicing of the tank Ref. AMM TASK 12-13-79-610-002.

(2)          If you let the engine stay open to freezing rain, ice or snow ; make sure that the fan turns freely.

(a)          If the fan does not turn freely, you must make the engine warm with hot air. You must do this step before an engine motoring.

(3)          Make sure that the hydraulic reservoirs are pressurized Ref. AMM TASK 29-14-00-614-002.

(4)          Make sure that the level of the hydraulic fluid in the reservoir is correct. If necessary, fill the reservoir Ref. AMM TASK 12-12-29-611-001 or Ref. AMM TASK 12-12-29-611-002.

NOTE:   You can do this test with the thrust reverser doors in open position (35 deg.) Ref. AMM TASK 78-36-00-010-040.

SUBTASK 73-29-00-865-050-A

D.           Make sure that this(these) circuit breaker(s) is(are) closed:

PANELDESIGNATIONFINLOCATION
49VUENGINE/1 AND 2/IGN/SYS A1JHA03
FOR FIN 1000EM1(ENGINE-1)
49VUFUEL/LP VALVE/MOT1/ENG11QGA08
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
49VUENGINE/1/HP FUEL SOV1KC1A01
121VUFUEL/LP VALVE/MOT2/ENG13QGM25
121VUENGINE/IGN/ENG1/SYS B3JH1P41
121VUENGINE/IGN/ENG1/SYS A BAT2JH1P39
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
FOR FIN 1000EM2(ENGINE-2)
49VUFUEL/LP VALVE/MOT1/ENG22QGA09
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
49VUENGINE/2/HP FUEL SOV1KC2A02
121VUFUEL/LP VALVE/MOT2/ENG24QGM26
121VUENGINE/IGN/ENG2/SYS B3JH2P42
121VUENGINE/IGN/ENG2/SYS A BAT2JH2P40
121VUENGINE/ENG2/FADEC B4KS2Q40

SUBTASK 73-29-00-941-050-A

E.            Connect a GROUND AIR-SUPPLY UNIT(HIGH PRESSURE) to the HP connectors or use the air from the APU Ref. AMM TASK 36-12-00-860-001 or Ref. AMM TASK 36-12-00-860-002. Make sure that the pressure of the air supply is between 25 psi (1.7 bar) and 55 psi (3.8 bar).

SUBTASK 73-29-00-860-051-A

F.            Do a check of the Panels to Prepare for Test.

(1)          On the AIR COND panel 30VU, make sure that the PACK 1/ENG 1 BLEED and PACK 2/ENG 2 BLEED push-button switches are released (the OFF legends are on).

(2)          On the maintenance panel 50VU, push then release the FADEC GND PWR 1(2) push-button switch (on this push-button switch, the ON legend is on).

(3)          On the left or right MCDU, get the SYSTEM REPORT/TEST, ENG page Ref. AMM TASK 31-32-00-860-012.

(4)          On the fuel part of the fuel control panel 40VU, push all the PUMPS push-button switches. On the push-button switches, the OFF legend go off.

(5)          On the ADIRS control display panel set the ADIRU to the NAV position. (the OFF light goes off).

4.            Procedure

SUBTASK 73-29-00-710-050-B

A.           Do this test:

Ref. Fig. FADEC Test Engine Motoring

NOTE:  This test is for the system 1. For the other system(s), use the indications between the parentheses.

ACTIONRESULT
1.Supply the engine with fuel.NOTE:If the fuel line or fuel equipment has been disconnected/removed dowstream of the LP valve before the FADEC test with engine motoring, start the fuel pumps and open the LP valve.
A.On the HYD/FUEL panel 40VU:-Make sure that the engine 1(2) pump is serviceable (the OFF legend of the ENG1(2) PUMP pushbutton switch must be off).
B.Open the circuit breaker 1KC1(2) to open the LP valve.-On the upper ECAM display unit this message comes into view:-ENG 1(2) LP VALVE OPEN-The single chime operates.-The MASTER CAUT light comes on.
2.Push the line key adjacent to the FADEC 1A (2A) indication.The ENGINE 1(2) MAIN MENU comes into view.
3.Push the line key adjacent to the FADEC TEST indication.The FADEC TEST menu comes into view.
4.On the MCDU, push the line key adjacent to the PUSH BUTTON TO START THE TEST indication.A new FADEC TEST menu comes into view
5.On the ENG panel 115VU, make sure that the ENG MODE CRANK/NORM/IGN/START selector switch is set to NORM.
6.On the ENG panel 115VU, set the ENG MASTER 1(2) control switch to ON and make sure that:-The engine operates (N2).-The oil pressure indication is positive.The indication «WARNING TEST ACTIVE» comes into view. When the test is finish the FADEC TEST REPORT comes into view
7.Push the line key adjacent to RETURNThe page TEST COMPLETE comes into view
8.Set the ENG MASTER 1(2) lever to OFF.
9.Push the line key adjacent to the RETURN indication until the SYSTEM REPORT/TEST ENG MENU comes into view.The ENGINE 1(2) MAIN MENU page comes into view
10.Do an ECU reset. To do this position the ENG MASTER control switch to ON then OFF.
11.Do the same procedure for channel B of the FADEC 1 (2).
12.On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.The MCDU menu comes into view.
13.Stop the MCDU.
14.Close the circuit breaker 1KC1(2) to close the LP valve.On the upper ECAM display unit:-The ENG 1(2) LP VALVE OPEN message goes out of view.
The master CAUT light goes off.

5.            Close-up

SUBTASK 73-29-00-860-052-A

A.           Check Panels for Close-up.

(1)          On the FUEL part of the fuel control panel 40VU, release all the PUMPS pushbutton switches. On the pushbutton switches, the OFF legends come on.

(2)          On the maintenance panel 50VU, push the ENG1 (2) FADEC GND PWR pushbutton switch. On the pushbutton switch, the ON legend goes off.

(3)          Set the ADIRU to the OFF position.

(4)          On the overhead panel 40VU, make sure that the ENG PUMP pushbutton switches are set to on (FAULT and OFF lights are off).

(5)          Install the protective covers on the probes and sensors Ref. AMM TASK 10-11-00-555-013.

SUBTASK 73-29-00-942-050-A

B.            Disconnect the HP ground air supply unit, or stop the APU.

SUBTASK 73-29-00-862-050-A

C.            De-energize the aircraft electrical circuits Ref. AMM TASK 24-41-00-862-002.

Read me first

All instructions and limitations given in those documents that relate to the resetting of systems both on the ground and in the air must be respected. No reset should be attempted without a thorough appreciation of the technical ramifications. No more than one computer should be reset at any one time. No reset should be attempted in flight unless specifically permitted by the QRH. Maintenance messages remaining after a reset require engineering investigation.

If you encounter an ECAM warning or caution that is not available on our website, please take a photo and send it to our Telegram.

Likewise, if you detect any discrepancies on the site, you can report them directly in our Telegram.