COM HF 1 EMMITTING
Cabin Intercommunication Data System(CIDS)
— RESET PROCEDURE—
- Reset breaker 2RE1 on panel 721VU
MEL STATUS: NO DISPATCH


COM HF 1 EMMITTING
Cabin Intercommunication Data System(CIDS)
— RESET PROCEDURE—
MEL STATUS: NO DISPATCH

All instructions and limitations given in those documents that relate to the resetting of systems both on the ground and in the air must be respected. No reset should be attempted without a thorough appreciation of the technical ramifications. No more than one computer should be reset at any one time. No reset should be attempted in flight unless specifically permitted by the QRH. Maintenance messages remaining after a reset require engineering investigation.






