COND _____TRIM AIR SYS FAULT

Air Conditioning System (Pack Controller) 1/2 (ACSC)

— RESET PROCEDURE—

*Do NOT reset in flight*

  • Pack Off & Check PFCV closed
  • ACSC1: Pull & Reset: X21, X22, Y18, Y19 & D08
  • ACSC2: Reset W21, W22, Y20 & Y21

Pull CBs for: 2 min

POST: 30 sec



Добавить комментарий

Read me first

All instructions and limitations given in those documents that relate to the resetting of systems both on the ground and in the air must be respected. No reset should be attempted without a thorough appreciation of the technical ramifications. No more than one computer should be reset at any one time. No reset should be attempted in flight unless specifically permitted by the QRH. Maintenance messages remaining after a reset require engineering investigation.