FUEL APU LP VALVE FAULT A320
APU ELECTRONIC CONTROL BOX (ECB)
— RESET PROCEDURE—
APU P/b ON.. 15 secs.. OFF
If no joy reset…
Pull & reset L41 & L42
Pull CBs for: 10 sec
POST: 3 sec
AMM TEST: 28-29-00-710-001-A — Operational Test of the APU Low Pressure Fuel Valve A320
TSM: 28-29-00-810-801-A — APU Fuel Supply Failure A320
MEL STATUS: 28-29-01