FUEL L/R XFR VALVE CLOSED A320
FUEL QUANTITY INDICATION COMPUTER (FQI)
— RESET PROCEDURE—
Pull in order… A13, M27 & L26
Reset in reverse order
Re-Align ADIRUs if illogical indications persist.
Pull CBs for: 8 sec
POST: 80 sec
AMM TEST: 28-46-00-740-001-A — Functional (BITE) Test A320
TSM: 28-15-00-810-801-A — Intercell XFR System Failure — Both Valves Remain Shut At Fuel Low Level A320
MEL STATUS: 28-50-01