Failure of the Right Yellow Elevator-Servocontrol Actuator Solenoid-Valve A320

CAUTION:           DO NOT SWAP FLIGHT CONTROL COMPUTERS. IF THERE IS A SHORT CIRCUIT, YOU WILL CAUSE DAMAGE TO A SERVICEABLE COMPUTER WHEN YOU SWAP THEM.

1. Possible Causes:

-SERVO CTL-R ELEVATOR, INBD Y (34CE2)

-ELAC-1 (2CE1)

-solenoid valve of the servocontrol 34CE2

-wiring of the SOL VLV1 signal from the servocontrol (34CE2) to the ELAC1 (2CE1)

-wiring from the ELAC1 (2CE1) COM part to the ELAC1 COM part

-wiring from the ELAC1 (2CE1) COM part to the ELAC1 MON part

-wiring from the ELAC1 (2CE1) MON part pins AE/13B and AE/12C to the first terminal block

2. Job Set-up Information

A. Referenced Information

REFERENCEDESIGNATION
Ref. AMM 27-34-51-000-001Removal of the Elevator Servo Control
Ref. AMM 27-34-51-000-005Removal of the Solenoid Valve of the Elevator Servo-Control Actuator
Ref. AMM 27-34-51-400-001Installation of the Elevator Servo Control
Ref. AMM 27-34-51-400-004Installation of the Solenoid Valve of the Elevator Servo-Control Actuator
Ref. ASM 27-93-07
Ref. AMM 27-93-34-000-001Removal of the ELAC
Ref. AMM 27-93-34-400-001Installation of the ELAC
Ref. AMM 27-96-00-710-020Operational Test of the Side Stick Assembly (Activation for the BITE Test)
Ref. AMM 27-96-00-740-001Operational Check of EFCS by BITE (Ground Scanning)

3. Fault Confirmation

SUBTASK 27-93-00-700-168-A

A. Test(s)

(1) Do the operational test of the side stick assembly (Activation for the BITE test) Ref. AMM 27-96-00-710-020.

NOTE:   Before you start the operational test procedure, release the FLT CTL/ELAC2 pushbutton switch (on this pushbutton switch, the OFF legend comes on).

(2) Do the BITE test of the EFCS (Ground Scanning) Ref. AMM 27-96-00-740-001.

4. Fault Isolation

SUBTASK 27-93-00-810-177-A

A. If the tests give the maintenance message R Y ELEV MODE VLV 34CE2:

(1) Remove the ELAC1 Ref. AMM 27-93-34-000-001.

(2) At the ELAC1 receptacle, do a check of the resistance between the pin AB/14K and the pin AE/14B Ref. ASM 27-93-07.

NOTE:   The resistance must be between 40 and 100 Ohms.

(a) If the resistance is less than 40 Ohms:

— at the inboard elevator servocontrol (34CE2), do a check of the resistance of the solenoid valve between the pin C/K and the pin C/L Ref. ASM 27-93-07.

NOTE: The resistance must be between 40 and 100 Ohms.

1 If the resistance values are out of the specified limits:

a Replace the solenoid valve of the servocontrol 34CE2 Ref. AMM 27-34-51-000-005 and Ref. AMM 27-34-51-400-004.

b             Do again a check of the resistance of the solenoid valve between the pin C/K and the pin C/L of the inboard elevator servocontrol (34CE2) (40 to 100 Ohms).

— If the resistance values are out of the specified limits:

. Replace SERVO CTL-R ELEVATOR, INBD Y (34CE2) Ref. AMM 27-34-51-000-001 and Ref. AMM 27-34-51-400-001.

. Replace ELAC-1 (2CE1) Ref. AMM 27-93-34-000-001 and Ref. AMM 27-93-34-400-001.

-If the resistance values are in the specified limits:

Replace ELAC-1 (2CE1) Ref. AMM 27-93-34-000-001 and Ref. AMM 27-93-34-400-001.

2 If the resistance values are in the specified limits:

a             Repair the wiring of the SOL VLV1 signal from the servocontrol (34CE2) to the ELAC1 (2CE1), from the pin C/K to the pin AB/14K and from the pin C/L to the pin AE/14B Ref. ASM 27-93-07:

b             Replace the ELAC-1 (2CE1) Ref. AMM 27-93-34-000-001 and Ref. AMM 27-93-34-400-001.

(b) If the resistance is more than 100 Ohms:

— at the inboard elevator servocontrol (34CE2), do a check of the resistance of the solenoid valve between the pin C/K and the pin C/L Ref. ASM 27-93-07.

NOTE:   The resistance must be between 40 and 100 Ohms.

1 If the resistance values are out of the specified limits:

a             Replace the solenoid valve of the servocontrol 34CE2 Ref. AMM 27-34-51-000-005 and Ref. AMM 27-34-51-400-004.

b             Do again a check of the resistance of the solenoid valve between the pin C/K and the pin C/L of the inboard elevator servocontrol (34CE2) (40 to 100 Ohms).

— If the resistance values are out of the specified limits:

. Replace the SERVO CTL-R ELEVATOR, INBD Y (34CE2) Ref. AMM 27-34-51-000-001 and Ref. AMM 27-34-51-400-001.

. Install the ELAC1 Ref. AMM 27-93-34-400-001.

— If the resistance values are in the specified limits:

Install the ELAC1 Ref. AMM 27-93-34-400-001.

2 If the resistance values are in the specified limits:

a             Repair the wiring of the SOL VLV1 signal from the servocontrol (34CE2) to the ELAC1 (2CE1), from the pin C/K to the pin AB/14K and from the pin C/L to the pin AE/14B Ref. ASM 27-93-07:

b             Install the ELAC1 Ref. AMM 27-93-34-400-001.

(c) If the resistance values are in the specified limits:

— See Para. (3).

(3) At the ELAC 1 receptacle, do a check of the insulation between pin AB/14K (pin AE/14B) and the ground.

NOTE:   The resistance must be more than 100 Megohms.

(a)          If the resistance is more than 100 Megohms:

—              Replace the ELAC-1 (2CE1) Ref. AMM 27-93-34-000-001 and Ref. AMM 27-93-34-400-001.

1             If the fault continues:

. Replace the solenoid valve Ref. AMM 27-34-51-000-005 and Ref. AMM 27-34-51-400-004.

2             If the fault continues:

. Replace the SERVO CTL-R ELEVATOR, INBD Y (34CE2) Ref. AMM 27-34-51-000-001 and Ref. AMM 27-34-51-400-001.

3             do a check of the wiring from the ELAC1 (2CE1) COM part to the ELAC1 COM part, from the pin AB/13K to the pin AB/13F Ref. ASM 27-93-07:

a             If the wiring is correct, see Para. 4_

b             If the wiring is not correct:

-repair it

— install the ELAC1 Ref. AMM 27-93-34-400-001

4             do a check of the wiring from the ELAC1 (2CE1) COM part to the ELAC1 MON part, from the pin AB/13E to the pin AE/12D Ref. ASM 27-93-07:

a             If the wiring is correct, see Para. 5_

b             If the wiring is not correct:

— repair it

— install the ELAC1 Ref. AMM 27-93-34-400-001

5 do a check and repair the wiring from the ELAC1 (2CE1) MON part pins AE/13B and AE/12C to the first terminal block Ref. ASM 27-93-07:

6 Install the ELAC-1 (2CE1) Ref. AMM 27-93-34-400-001.

(b) If the resistance is less than 100 Megohms:

— at the SERVO CTL-R ELEVATOR, INBD Y (34CE2), do a check of the insulation of the solenoid valve between pin C/K (pin C/L) and the ground.

1 If the resistance is less than 100 Megohms:

Replace the solenoid valve Ref. AMM 27-34-51-000-005 and Ref. AMM 27-34-51-400-004.

a Do again a check of the insulation of the solenoid valve between pin C/K (pin C/L) and the ground.

If the resistance is less than 100 Megohms:

. Replace the SERVO CTL-R ELEVATOR, INBD Y (34CE2) Ref. AMM 27-34-51-000-001 and Ref. AMM 27-34-51-400-001.

. Replace the ELAC-1 (2CE1) Ref. AMM 27-93-34-000-001 and Ref. AMM 27-93-34-400-001.

2 If the resistance is more than 100 Megohms:

a             Repair the wiring of the solenoid valve signal from the SERVO CTL-R ELEVATOR, INBD Y (34CE2) to the ELAC-1 (2CE1).

b             Replace the ELAC-1 (2CE1) Ref. AMM 27-93-34-000-001 and Ref. AMM 27-93-34-400-001.

SUBTASK 27-93-00-700-169-A

B. Do the test given in Para. 3.

Read me first

All instructions and limitations given in those documents that relate to the resetting of systems both on the ground and in the air must be respected. No reset should be attempted without a thorough appreciation of the technical ramifications. No more than one computer should be reset at any one time. No reset should be attempted in flight unless specifically permitted by the QRH. Maintenance messages remaining after a reset require engineering investigation.