Internal Failure of the ADR 1 A320

1. Possible Causes:

-ADIRU-1 (1FP1)

2. Job Set-up Information

A. Referenced Information

REFERENCEDESIGNATION
Ref. AMM 34-12-34-000-001Removal of the ADIRU
Ref. AMM 34-12-34-400-001Installation of the ADIRU
Ref. AMM 34-13-00-740-003System Test of the Air Data Reference (ADR)

3. Fault Confirmation

SUBTASK 34-13-00-740-050-A

A. Test(s)

(1) Do the system test of the ADR (system 1) Ref. AMM 34-13-00-740-003.

4. Fault Isolation

SUBTASK 34-13-00-810-050-B

A. If the test gives the maintenance message ADIRU1 (1FP1):

— Replace ADIRU-1 (1FP1), Ref. AMM 34-12-34-000-001 and Ref. AMM 34-12-34-400-001.

Read me first

All instructions and limitations given in those documents that relate to the resetting of systems both on the ground and in the air must be respected. No reset should be attempted without a thorough appreciation of the technical ramifications. No more than one computer should be reset at any one time. No reset should be attempted in flight unless specifically permitted by the QRH. Maintenance messages remaining after a reset require engineering investigation.