L/G LGCIU 1/2 FAULT A320

Landing Gear Control Interface Unit (LGCIU)

— RESET PROCEDURE—

*DO NOT RESET BOTH LGCIUs TOGETHER*

*DO NOT DE-POWER EITHER LGCIUs FOR MORE THAN 30 secs*

DEPRESSURISE G HYD SYS

LGCIU1: PULL C09

LGCIU2: PULL Q35

NEO (ALL):

LGCIU1: PULL C09, Q34 & R32

LGCIU2: PULL Q35, R33

Pull CBs for: MAX 30 sec

POST: 1 sec

AMM TEST: 32-69-00-740-001-A — BITE Check of LGCIU A320
TSM: 32-31-00-810-802-A — LGCIU Fault A320
MEL STATUS: 32-31-01 OR NO DISPATCH


Добавить комментарий

Read me first

All instructions and limitations given in those documents that relate to the resetting of systems both on the ground and in the air must be respected. No reset should be attempted without a thorough appreciation of the technical ramifications. No more than one computer should be reset at any one time. No reset should be attempted in flight unless specifically permitted by the QRH. Maintenance messages remaining after a reset require engineering investigation.

If you encounter an ECAM warning or caution that is not available on our website, please take a photo and send it to our Telegram.

Likewise, if you detect any discrepancies on the site, you can report them directly in our Telegram.