FWS SDAC 1/2 FAULT A320
System Data Acquisition Computer (SDAC)
— RESET PROCEDURE—
SDAC1: PULL F02, F04, F05, Q03 & Q04
SDAC2: PULL F03, F05, Q02, Q05 & Q06
Pull CBs for: 2 sec
POST: 5 sec
AMM TEST: 31-50-00-710-001-A — Ground Scanning of the Central Warning System A320
TSM: 31-54-00-810-810-A — Failure of the SDAC 1 A320
MEL STATUS: 31-55-01