L/G _____LGCIU 1/2 FAULT

Landing Gear Control Interface Unit (LGCIU)

— RESET PROCEDURE—

*DO NOT RESET BOTH LGCIUs TOGETHER*

*DO NOT DE-POWER EITHER LGCIUs FOR MORE THAN 30 secs*

  • DEPRESSURISE G HYD SYS
  • LGCIU1: PULL C09
  • LGCIU2: PULL Q35

NEO (ALL):

  • LGCIU1: PULL C09, Q34 & R32
  • LGCIU2: PULL Q35, R33

Pull CBs for: MAX 30 sec

POST: 1 sec

MEL STATUS: 32-31-01 OR NO DISPATCH



Leave a Reply

Your email address will not be published. Required fields are marked *

Read me first

All instructions and limitations given in those documents that relate to the resetting of systems both on the ground and in the air must be respected. No reset should be attempted without a thorough appreciation of the technical ramifications. No more than one computer should be reset at any one time. No reset should be attempted in flight unless specifically permitted by the QRH. Maintenance messages remaining after a reset require engineering investigation.