SMOKE FWD/AFT CRG DET FAULT A320
Smoke Detection Control Unit. (SDCU)
— RESET PROCEDURE—
Pull & Reset:
- Pull C05, C06, T17 & T18 Wait 10 secs
- Reset C05 & C06 simultaneously
- Within 2 secs reset T17 & T18 simultaneously
Pull CBs for: 10 sec
POST: 2 mins
AMM TEST: 23-73-00-740-005-B — Interface and Power-Up Test of the CIDS A320
TSM: 26-16-00-810-805-A — Cargo-Compartment Smoke Warning(s) without Fire A320
MEL STATUS: 26-16-01, 26-16-02