Cargo-Compartment Smoke Warning(s) without Fire A320

1. Possible Causes:

-CIDS-SDF software

-oil leak of the APU

-environmental conditions such as humidity, dust, etc.

2. Job Set-up Information

A. Referenced Information

REFERENCEDESIGNATION
Ref. 05-50-00-810-831-AIdentification of the Cause for Cabin Odor, Smoke or Fume
Ref. AMM 12-33-21-618-001Pre-conditioning through the LP Ground Connection
Ref. AMM 26-16-00-910-801Report the Cargo-Compartment Smoke Warning Event

3. Fault Confirmation

SUBTASK 26-16-00-710-054-A

A. Test

(1) Some CIDS-SDF software can cause a spurious fault message for the smoke alarm to occur (Refer to TFU 23.73.00.101).

(2) Make sure that:

(a) There was no real smoke condition in the related area.

(b) There was no other cause, such as smoke source external to the aircraft, which could cause the smoke warning.

(c) The APU (Auxiliary Power Unit) operated during the smoke warning.

(3) Do the pre-conditioning of the air conditioning system with the APU Ref. AMM 12-33-21-618-001.

4. Fault Isolation

SUBTASK 26-16-00-810-059-A

A. If you smell fumes in the cabin during the pre-conditioning with the APU:

(1) Do the troubleshooting procedure for cabin odors or smoke Ref. TSM TASK 05-50-00-810-831.

NOTE: This fault can be caused by a smoke event because of an oil leak of the APU or environmental conditions such as humidity, dust, etc.

SUBTASK 26-16-00-810-135-A

B. Airbus recommends that you record the cargo-compartment smoke warning event in the report form Ref. AMM 26-16-00-910-801.

5. Close-up

SUBTASK 26-16-00-860-054-A

A. Put the aircraft back to its initial configuration.

Read me first

All instructions and limitations given in those documents that relate to the resetting of systems both on the ground and in the air must be respected. No reset should be attempted without a thorough appreciation of the technical ramifications. No more than one computer should be reset at any one time. No reset should be attempted in flight unless specifically permitted by the QRH. Maintenance messages remaining after a reset require engineering investigation.