TSM Lavatory Smoke Detection Failed A320
1. Possible Causes:
-DIR-CIDS, 1 (101RH)
-DIR-CIDS, 2 (102RH)
-wiring
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
| Ref. AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| Ref. ASM 23-73-01 | |
| Ref. AMM 23-73-34-000-001 | Removal of the Cabin Intercommunication Data System (CIDS) Director |
| Ref. AMM 23-73-34-400-001 | Installation of the Cabin Intercommunication Data System (CIDS) Director |
3. Fault Confirmation
SUBTASK 26-17-00-710-094-A
A. Test
(1) Do the CIDS Interface and Power-Up Test via the CFDS Ref. AMM 23-73-00-740-005.
4. Fault Isolation
SUBTASK 26-17-00-810-130-A
A. If the test gives a different maintenance message:
— Do the trouble shooting procedure related to the maintenance message.
SUBTASK 26-17-00-810-131-A
B. If the test gives the maintenance message
CIDS(102RH)-SDF2 BUS / CIDS(101RH)-SDF1 or CIDS(101RH)-SDF1 BUS / CIDS(102RH)-SDF2 or NO LAV DATA/CIDS(101RH)-SDF1 BUS/CIDS(102RH)-SDF2 or NO LAV DATA/CIDS(102RH)-SDF2 BUS/CIDS(101RH)-SDF1:
(1) Replace the DIR-CIDS, 1 (101RH) Ref. AMM 23-73-34-000-001 and Ref. AMM 23-73-34-400-001.
(2) If the fault continues:
— Replace the DIR-CIDS, 2 (102RH) Ref. AMM 23-73-34-000-001 and Ref. AMM 23-73-34-400-001.
(3) If the fault continues:
— Do a check and repair the wiring between the CIDS-SDF1 (AA15C and AA15H) and CIDS-SDF2 (AA11J and AA11K) Ref. ASM 23-73-01.
(4) If the fault continues:
— Do a check and repair the wiring between the CIDS-DIR1 (AA13A and AA13B) and CIDS-DIR2 (AA13E and AA13F) Ref. ASM 23-73-01.
SUBTASK 26-17-00-710-095-A
C. Do the test as given in the Para. 3.
5. Close-up
SUBTASK 26-17-00-860-071-A
A. Put the aircraft back to its initial configuration.