F/CTRL _____SPD BRK 2 FAULT
SPOILER ELEVATOR COMPUTER 1/2/3 (SEC)
— RESET PROCEDURE—
P/b Off 10 secs
If no joy reset…
Pull & reset
- SEC 1: Pull B08
- SEC 2: Pull Q18
- SEC 3: Pull Q19
NEO(CFM): SEC1 PULL B08 & B01
Pull CBs for: 5 sec
POST: 18 sec
MEL STATUS: 27-94-01(02)(03)