FWS _____SDAC 1+2 FAULT
System Data Acquisition Computer (SDAC)
— RESET PROCEDURE—
SDAC1: PULL F02, F04, F05, Q03 & Q04
SDAC2: PULL F03, F05, Q02, Q05 & Q06
Pull CBs for: 2 sec
POST: 5 sec
MEL STATUS: NO DISPATCH


FWS _____SDAC 1+2 FAULT
System Data Acquisition Computer (SDAC)
— RESET PROCEDURE—
SDAC1: PULL F02, F04, F05, Q03 & Q04
SDAC2: PULL F03, F05, Q02, Q05 & Q06
Pull CBs for: 2 sec
POST: 5 sec
MEL STATUS: NO DISPATCH

All instructions and limitations given in those documents that relate to the resetting of systems both on the ground and in the air must be respected. No reset should be attempted without a thorough appreciation of the technical ramifications. No more than one computer should be reset at any one time. No reset should be attempted in flight unless specifically permitted by the QRH. Maintenance messages remaining after a reset require engineering investigation.