NAV _____ADR DISAGREE

Air Data Inertial Reference Unit (ADIRU)

— RESET PROCEDURE—

Off for 15 secs min then on. If no joy reset…

Pull & reset

  • ADIRU 1: C02, F06 & F07
  • ADIRU 2: N04, N06, N08 & N10
  • ADIRU 3: N03, N05, N07, N09 & F09

OTHERWISE RESET ONSIDE AOA SYS

Pull CBs for: 20 sec

POST: 5 sec

MEL STATUS: NO DISPATCH



Leave a Reply

Your email address will not be published. Required fields are marked *

Read me first

All instructions and limitations given in those documents that relate to the resetting of systems both on the ground and in the air must be respected. No reset should be attempted without a thorough appreciation of the technical ramifications. No more than one computer should be reset at any one time. No reset should be attempted in flight unless specifically permitted by the QRH. Maintenance messages remaining after a reset require engineering investigation.