F/CTRL _____ELAC 1/2 PITCH FAULT
Elevator & Aileron Computer 1/2 (ELAC)
— RESET PROCEDURE—
- ELAC P/b Off 10 secs
If no joy reset …
Pull & reset
- ELAC 1: Pull B11
- ELAC 2: Pull R20
NEO (All):
- ELAC 1: Pull B11, A01
- ELAC 2: Pull R20, A02
Pull CBs for: 2 min
POST: 10 sec
MEL STATUS: 27-93-01, 27-93-02