F/CTRL ELAC 1/2 FAULT A320
ELEVATOR & AILERON COMPUTER 1/2 (ELAC)
— RESET PROCEDURE—
ELAC P/b Off 10 secs
If no joy reset…
Pull & reset
ELAC 1: Pull B11
ELAC 2: Pull R20
NEO(ALL):
ELAC 1: Pull B11, A01
ELAC 2: Pull R20, A02
Pull CBs for: 2 min
POST: 10 sec
AMM TEST: 27-93-00-710-001-A — Operational Test of the ELACs A320
TSM: 27-93-00-810-896-A — Failure of ELAC1 A320
MEL STATUS: 27-93-01, 27-93-02