F/CTRL _____ELAC 1/2 PITCH FAULT

Elevator & Aileron Computer 1/2 (ELAC)

— RESET PROCEDURE—

  • ELAC P/b Off 10 secs

If no joy reset …

Pull & reset

  • ELAC 1: Pull B11
  • ELAC 2: Pull R20

NEO (All):

  • ELAC 1: Pull B11, A01
  • ELAC 2: Pull R20, A02

Pull CBs for: 2 min

POST: 10 sec

MEL STATUS: 27-93-01, 27-93-02



Leave a Reply

Your email address will not be published. Required fields are marked *

Read me first

All instructions and limitations given in those documents that relate to the resetting of systems both on the ground and in the air must be respected. No reset should be attempted without a thorough appreciation of the technical ramifications. No more than one computer should be reset at any one time. No reset should be attempted in flight unless specifically permitted by the QRH. Maintenance messages remaining after a reset require engineering investigation.