VENT SKIN VALVE FAULT A320
Avionics Equipment Ventilation Controller.(AEVC)
— RESET PROCEDURE—
DO NOT RESET IN FLIGHT!
Pull & Reset:
- Pull & Reset Y17
- IF NO JOY… Pull & Reset D05, D06 & Y17
Pull CBs for: 10 sec
POST: 85 sec
AMM TEST: 21-26-00-710-001-A — Operational Check of the Avionics Equipment Ventilation-System via MCDU
TSM: 21-26-00-810-830-A — Failure of the Skin Air Valve A320
MEL STATUS: 21-26-04, 21-26-05