MMEL 36-11-01A

Repair interval C

Nbr installed 2

Nbr required 1

Placard Yes

One may be inoperative provided that the associated engine bleed air supply system is considered inoperative.One may be inoperative provided that:
1) ETOPS is not conducted, and
2) The associated ENG BLEED pb-sw is set to OFF, and
3) The X BLEED selector is set to OPEN, and
4) The speedbrakes are operative.


Refer to OpsProc 36-11-01A Engine Bleed Air Supply System (non-ETOPS flights)

For details see MEL for your Company

— RESET PROCEDURE—

36-11-00-740-001-A BITE Test of the BMC 1(2)

36-11-34 PB 401 BLEED MONITORING COMPUTER (BMC) replace



Добавить комментарий

Read me first

All instructions and limitations given in those documents that relate to the resetting of systems both on the ground and in the air must be respected. No reset should be attempted without a thorough appreciation of the technical ramifications. No more than one computer should be reset at any one time. No reset should be attempted in flight unless specifically permitted by the QRH. Maintenance messages remaining after a reset require engineering investigation.

If you encounter an ECAM warning or caution that is not available on our website, please take a photo and send it to our Telegram.

Likewise, if you detect any discrepancies on the site, you can report them directly in our Telegram.

  • Рубрики
  • Social Icons

    Gallery